dc.description.abstractA method is proposed for suppressing uncontrollable noise factors in the form of local variations in the electrophysical properties of the weakly magnetic substrate material of tested objects during eddy current measurements of the thickness of dielectric coatings in the medium frequency range up to 100 kHz. As opposed to methods focused on complicating measuring instruments, in particular the use of multi-frequency techniques, swept-frequencies, resource-intensive numerical techniques for computer-based solution of inverse problems, etc., the new approach to solving this problem involves the use of the Taguchi method for robust parameter design of optimal eddy current probes in terms of improving signal-to-noise ratios, which ultimately ensures minimal variability of the useful signal without actually eliminating uncontrollable interference inherent in the tested objects. This made the medium frequency ECPs competitive for the specified measurements compared to high frequency ones due to the simplification of the hardware part of the gauges, the removal of the problem of equipping them with special sensors, and the reduction of their cost. Because of conducting a variance ANOVA analysis, the statistical influence of the design parameters of thickness gauge probes on the characteristics of the output signal was determined. This enabled the establishment of technical requirements for the accuracy of measuring devices in the manufacturing process, as well as the maintenance of operating parameters, specifically frequency and excitation current, within acceptable limits without significantly compromising the optimal signal-to-noise ratio.uk_UA
dc.language.isoenuk_UA
dc.publisherPLoS Oneuk_UA
dc.subjectdielectric coatingsuk_UA
dc.subjectweakly magnetic substrateuk_UA
dc.subjectsuppression of uncontrollable noiseuk_UA
dc.subjecttaguchi methoduk_UA
dc.subjectdesign of experimentuk_UA
dc.subjectoptimal design of the eddy current probeuk_UA
dc.subjectsignal-to-noise ratiouk_UA
dc.subjectsignal stability to noiseuk_UA
dc.titleEddy current measurements of dielectric coating thickness on a weakly magnetic substrate within the medium frequency range.uk_UA
dc.typeArticleuk_UA
dc.citation.volume21uk_UA
dc.citation.issue1uk_UA
dc.citation.spagee0340200-1uk_UA
dc.citation.epagee0340200-16uk_UA
dc.identifier.doihttps://doi.org/10.1371/journal.pone.0340200-